Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.

Fire rated 2 hour shaft wall assembly.

Fire safety caution passing a fire test in a controlled laboratory setting and or certifying or labeling a product as having a one hour two hour or any other fire resistance or protection rating and therefore as acceptable for use in certain fire rated assemblies systems does not mean that either a particular assembly system incorporating the product or any given piece of the product. Use special fiberglass rated for use in firewalls. These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies. Face layer 5 8 15 9 mm toughrock fireguard x products or 5 8 15 9 mm densarmor plus fireguard gypsum panels installed vertically to studs with 1 58 type s.

Sw 106 1 hour shaftwall with deflection track. The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels. Deflection 5 7. Type of assembly required assembly rating hours minimum fire door fire assembly fire rating.

Mount a 1 1 2 inch fiberglass barrier inside the studs. Ul design u499 w419. Base layer of 5 8 15 9 mm toughrock fireguard x products or 2 8 15 9 mm densarmor plus fireguard gypsum panels installed horizontally or vertically with 1 type s screws 24 o c. For testing requirements see section 715 4 3.

Two hour three hour and four hour rated walls require additional protection of penetrations since they must resist higher temperatures than a one hour rated wall and for a longer time. Head of wall firestop system gypsum board fire trak shadowline. Elements of buildings the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated walls ceiling and floor assemblies. 2 hour vertical shaftwall system proroc shaftwall systems provide one two or three hour fire resistance ratings in non load bearing configurations.

The systems are designed to withstand the intermittent surges of air pressure caused by fast moving elevator cabs. U498 2 hour stairwell construction 1 fire shield shaftliner j track 020 0329 3 leg 0329 only view a a i stud 020 0329 u499 1 hour shaftwall allowable wall heights for 1 hour fire rated i stud assemblies stud stud min. Two doors each with a fire protection rating of 1 1 2 hours installed on opposite side of the same opening in a fire wall shall be deemed equivalent in fire protection rating to one 3 hour door.

Pin De Claire Andrew En Arq Sec Dtl

Pin De Claire Andrew En Arq Sec Dtl

Pin On Architectural Details

Pin On Architectural Details

Fusible Link Louver Listed Fusible Link Type Louvers To A Maximum Size Of 24 X 24 Are Permitted In 1 1 2 Hour And 3 4 Hou Fire Doors Glass Lighting Mounting

Fusible Link Louver Listed Fusible Link Type Louvers To A Maximum Size Of 24 X 24 Are Permitted In 1 1 2 Hour And 3 4 Hou Fire Doors Glass Lighting Mounting

09 21 13 112 Plaster Wall Solid Plaster Partition Wall Design Plaster Walls Partition Wall

09 21 13 112 Plaster Wall Solid Plaster Partition Wall Design Plaster Walls Partition Wall

Source : pinterest.com