16 14 gauge.
Fire rated double egress doors.
18 gauge frames single swing frame 1 1 2 hour rated.
Fire rated up to 3 hours.
A double egress hollow metal frame is for a pair of doors in which the doors can only swing in the opposite direction.
An exception to latching for fire rated openings is allowed by the ibc for double egress doors in corridors that are in a smoke barrier.
Double egress frames are typically used in corridors of hospitals schools and nursing homes where the control of traffic is important.
Fire window frame knock down construction drywall walls only 1 1 2 hour rated.
707 single pairs double egress up to 3 hour rated.
Astragals are required on.
Depth 5 1 4 14 fire label.
Caution for fire rated applications the wood door manufa.
Fire rated steel doors play a vital role in keeping people safe and minimizing property damage during a fire.
Yes wood doors can be used and installed in most hollow metal frame applications including fe series and de series double egress frames.
Accepts existing opening metal wood stud or masonry anchors.
Fe series double egress door frames are used for masonry applications and meet requirements for commercial and institutional heavy to maximum duty applications.
16 gauge steel cold rolled.
3 hour fire rated pairs.
Eliason corporation for decades has been recognized as the premier manufacturer of custom door solutions.
Fire labeled doors available.
Fire rated healthcare windstorm.
1 min for double egress 9 16 min for single or pair swing 5 8 min 1 15 16 5 8 min max 4 5 8 1 min 1 3 8 min 1 2 min 3 min 13 max 1 max 4 min 15 max.
Metal fire doors are an economical alternative to wood fire doors when more than a 20 minute rating is required.
Our experienced designers and door builders welcome your ideas and look forward to working with you to create a high quality entrance or vendor door that is designed specifically for your application and decor.
Door mounts in center of frame.
Frames may have combinations of the previous backbend types.
The omission of positive latching devices must be included in the door manufacturer s listing.
727 single pairs double egress up to 3 hour rated.
Labeled fire doors control the spread of fire and smoke for up to 3 hours.
Up to 3 hours ul10b and ul10c underwriters laboratories applied only warnock hersey applied only series se step 2 shown.
These requirements apply to all fire rated doors frames and windows.
Double egress series se1 or se2.
State and local building code authorities may also allow latching to be omitted in certain openings.